CGLDJ - ALKALINE BATTERIES,NO MERCURY FORMULA-AN ARTICLE
- MSDS: CGLDJ
- Manufacturer: RAYOVAC CORP
- Product Name: ALKALINE BATTERIES,NO MERCURY FORMULA-AN ARTICLE
- National Stock Number: 6135-00-826-4798
Product Identification
Product ID:ALKALINE BATTERIES,NO MERCURY FORMULA-AN ARTICLE
MSDS Date:10/15/1997
FSC:6135
NIIN:00-826-4798
MSDS Number: CGLDJ
Responsible Party
MADISON, WI 53711
US
Emergency Phone: 608-275-4856
Info Phone: 608-275-3340/FAX 608-275-4992
Preparer: MARSHEL L. BEASON JR
Cage: 77542
Contractor
Telephone: 608-275-4735/800-255-3924
Cage: 77542
Ingredients
MANGANESE DIOXIDE
CAS: 1313-13-9
RTECS: OP0350000
Fraction By Weight: 32-38%
OSHA PEL 5 MG MN/M3 CEILING
ACGIH TLV: 5 MG MN/M3 9394
STEEL (IRON)
CAS: 7439-89-6
RTECS: NO4565500
Fraction By Weight: 19-23%
ZINC. SARA NOTIFICATION NOT REQUIRED. THESE PRODUCTS ARE
CAS: 7440-66-6
RTECS: ZG8600000
Fraction By Weight: 11-16%
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: 9-13%
POTASSIUM HYDROXIDE (CERCLA). NOTIFICATION NOT REQUIRED. AN
CAS: 1310-58-3
RTECS: TT2100000
Fraction By Weight: 5-9%
OSHA PEL C 2 MG/M3
ACGIH TLV: C 2 MG/M3; 9495
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
CARBON
CAS: 7440-44-0
RTECS: FF5250100
Fraction By Weight: 3-5%
OSHA PEL 3.5 MG/M3
ACGIH TLV: 3.5 MG/M3; 9495
BARIUM SULFATE
CAS: 7727-43-7
RTECS: CR0600000
Fraction By Weight: <5%
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST; 9596
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:THERE ARE NO HEALTH HAZARDS UNDER
NORMAL CONDITIONS OF USE SINCE THE CORROSIVE INGREDIENTS ARE
CONTAINED IN A SEALED BATTERY CASE. IN THE EVENT THAT BATTERY
RUPTURES, CONTACT WITH CORROSIVE INGREDIENT S MAY CAUSE IRRITATION
AND CHEMICAL BURNS OF EYES AND SKIN.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:THERE ARE NO EFFECTS OF OVEREXPOSURE UNDER
NORMAL CONDITIONS OF USE. IF BATTERY CASE IS RUPTURED, CONTACT WITH
CORROSIVE INGEDIENTS MAY CAUSE IRRITATION AND CHEMICAL BURNS OF
EYES AND SKIN.
Medical Cond Aggravated by Exposure:NONE
First Aid
First Aid:IN EVENT OF BATTERY RUPTURES AND CONTACT OF CORROSIVE
INGREDIENTS WITH EYES OR SKIN: EYES: FLUSH WITH LARGE AMOUNTS OF
WATER. GET MEDICAL ATTENTION. SKIN: REMOVE CONTAMINATED CLOTHING.
WASH SKIN WITH SOAP AND WATER. IF ADVERSE SYMPTOMS DEVELOP, GET
MEDICAL ATTENTION. LAUNDER CONTAMINATED CLOTHING BEFORE REUSE.
Fire Fighting
Flash Point:NONE
Lower Limits:NONE
Upper Limits:NONE
Extinguishing Media:IN BULK STORAGE AREAS, USE FOAM OR DRY POWDER.
WATER MAY CAUSE ELECTRICAL SHORTS.
Fire Fighting Procedures:AS WITH ANY FIRE, WEAR SELF-CONTAINED
BREATHING APPARATUS TO AVOID INHALATION OF HAZARDOUS DECOMPOSITION
PRODUCTS.
Unusual Fire/Explosion Hazard:LIKE ANY SEALED CONTAINER, BATTERY CELLS
MAY RUPTURE WHEN EXPOSED TO EXCESSIVE HEAT, THIS COULD RESULT IN
RELEASE OF CORROSIVE MATERIALS.
Accidental Release
Spill Release Procedures:IN EVENT OF BATTERY RUPTURE, COLLECT ALL
RELEASED MATERIAL IN A PLASTIC BAG FOR WASTE DISPOSAL. REPORT ALL
REPORTABLE SPILLS IN ACCORDANCE WITH STATE AND LOCAL REGULATIONS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE IN A DRY PLACE. STORING
UNPACKAGED CELLS TOGETHER COULD RESULT IN CELL SHORTING AND HEAT
BUILD-UP. DO NOT RECHARGE THESE BATTERIES.
Other Precautions:DO NOT PACK, STORE, OR SHIP USED BATTERIES IN TIGHTLY
SEALED CONTAINERS. THE SLOW EVOLUTION OF HYDROGEN GAS FROM USED
BATTERIES MAY PRODUCE CONTAINER OVER-PRESSURE OR EXPLOSIVE
CONDITIONS.
Exposure Controls
Respiratory Protection:NONE NORMALLY REQUIRED. HOWEVER, AS IN ANY FIRE
SITUATION, USE SELF-CONTAINED BREATHING APPARATUS (SCBA).
Ventilation:NO SPECIAL VENTILATION REQUIRED. NORMAL WORKPLACE
VENTILATION IS ADEQUATE.
Protective Gloves:NONE NORMALLY REQUIRED.
Eye Protection:NONE NORMALLY REQUIRED.
Other Protective Equipment:NONE NORMALLY REQUIRED.
Work Hygienic Practices:NORMAL WORKPLACE HYGENIC PRACTICES RECOMMENDED.
Supplemental Safety and Health
MANUFACTURE STATES THAT THESE BATTERIES ARE EXEMPT ARTICLES AND ARE NOT
SUBJECT TO THE 29 CFR 1910.1200 OSHA REQUIREMENT AND THAT THESE
BATTERIES ARE SUITABLE FOR DISPOSAL IN ORDINARY LANDFILLS.
Chemical Properties
HCC:N1
Appearance and Odor:BATTERY, ALL SIZES. ENCASED CYLINDRICAL OR
RECTANGULAR SHAPE.
Stability
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:AVOID ELECTRICAL SHORTING.
Hazardous Decomposition Products:OXIDES OR FUMES OF MANGANESE, ZINC,
POTASSIUM, BARIUM.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
Disposal
Waste Disposal Methods:SHREDDED PER TOXICITY LEACHATE PARAMETERS,
TESTED PER SW 846, 3RD ED.,"TEST METHOD FOR SOLID WASTE", CERTIFIED
LAB ANALYSES INDICATED THESE BATTERY TYPES HAVE NO HAZARDOUS WASTE
CHARACTERISTICS, CAN B E LANDFILLED IF ALL REGULATIONS ARE COMPLIED
WITH.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.